"False"
Skip to content
umu.se
For students
Library
For staff
Login
Students
All students must change their password since 7 May.
Edit
Edit content at umu.se
Svensk webbplats
Search
Menu
X close menu
Menu
Search
Search within:
Search within:
All
Education
Research
Staff
Student web
News
Other search services
Find courses and programmes
Library search tool
Search the legal framework
Main menu hidden.
Login
Students
All students must change their password since 7 May.
Edit
Edit content at umu.se
Svenska
Jonas Andersson
Research qualifications:
Docent
Contact
E-mail
jonas.s.andersson@umu.se
Phone
+46 90 785 27 96
Works at
Affiliation
Adjunct associate professor at
Department of Diagnostics and Intervention
Section: Biomedical engineering and Radiation Physics
Location
10C, Norrlands universitetssjukhus
Umeå universitet, 901 85 Umeå
Publications
Publications
2024
Proton stopping power ratio prediction using photon-counting computed tomography and deep learning
Medical Imaging 2024: Physics of Medical Imaging - proceedings, part 1
Larsson, Karin; Hein, Dennis; Huang, Ruihan; et al.
2024
The use of dose management systems in Europe: results of an ESR EuroSafe imaging questionnaire
Insights into Imaging
, Vol. 15, (1)
Loose, Reinhard; Vaño, Eliseo; Ammon, Josefin; et al.
2024
If you can make it, you can share it – Perspectives on the first DIY-fair at the European congress of medical physics (ECMP, DUBLIN 2022)
Physica medica (Testo stampato)
, Elsevier 2024, Vol. 118
Nieminen, Miika T.; Hernandez-Giron, Irene; Andersson, Jonas
2023
The influence of dual-energy computed tomography image noise in proton therapy treatment planning
Physics and Imaging in Radiation Oncology
, Elsevier 2023, Vol. 28
Näsmark, Torbjörn; Andersson, Jonas
2023
Education and training in radiation protection in Europe: results from the EURAMED Rocc-n-Roll project survey
Insights into Imaging
, Springer 2023, Vol. 14, (1)
Santos, Joana; Foley, Shane; Andersson, Jonas; et al.
2022
Education and training in radiation protection in Europe: an analysis from the EURAMED rocc-n-roll project
Insights into Imaging
, Springer 2022, Vol. 13, (1)
Rainford, Louise; Santos, Joana; Alves, Francisco; et al.
2022
Notifications and alerts in patient dose values for computed tomography and fluoroscopy-guided interventional procedures
European Radiology
, Springer 2022, Vol. 32 : 5525-5531
Vano, Eliseo; Loose, Reinhard; Frija, Guy; et al.
2021
Estimation of patient skin dose in fluoroscopy: summary of a joint report by AAPM TG357 and EFOMP
Medical physics (Lancaster)
, John Wiley & Sons 2021, Vol. 48, (7) : e671-e696
Andersson, Jonas; Bednarek, Daniel R.; Bolch, Wesley; et al.
2021
Artificial intelligence and the medical physics profession - A Swedish perspective
Physica medica (Testo stampato)
, Elsevier 2021, Vol. 88 : 218-225
Andersson, Jonas; Nyholm, Tufve; Ceberg, Crister; et al.
2021
Proton stopping power prediction based on dual-energy CT-generated virtual mono-energetic images
Medical physics (Lancaster)
, John Wiley & Sons 2021, Vol. 48, (9) : 5232-5243
Näsmark, Torbjörn; Andersson, Jonas
2021
Dosimetric quantities and effective dose in medical imaging: a summary for medical doctors
Insights into Imaging
, Springer Berlin/Heidelberg 2021, Vol. 12, (1)
Vano, Eliseo; Frija, Guy; Loose, Reinhard; et al.
2020
[Book review] The Physics of CT Dosimetry – CTDI and Beyond, by Robert L. Dixon
Physica medica (Testo stampato)
, ELSEVIER SCI LTD 2020, Vol. 69 : 126-126
Andersson, Jonas
2020
Introducing PySkinDose, a novel framework for patient peak skin dose estimation in interventional radiology
ECR - European Congress of Radiology, Virtual meeting, July 15-19, 2020
Hellström, Max; Granberg, Christoffer; Lundman, Josef; et al.
2020
A Swedish implementation of manufacturer specific quality assurance for radiological equipment
ECR 2020 - European Congress of Radiology, Virtual Meeting, July 15-19, 2020
Sundström, Henrik; Sjöberg, Johan; Andersson, Jonas
2019
Estimating Patient Organ Dosewith Computed Tomography: A Review of Present Methodologyand Required DICOM Information: A Joint Report ofAAPM Task Group 246 and the European Federationof Organizations for Medical Physics (EFOMP)
AAPM report
Andersson, Jonas; Pavlicek, William; Al-Senan, Rani; et al.
2018
A novel system for quality assurance of radiology equipment
EuroSafe Imaging 2018 / ESI-0064
Andersson, Jonas; Granberg, Christoffer; Riklund, Katrine
2018
Applying three different methods of measuring CTDI
free air
to the extended CTDI formalism for wide-beam scanners (IEC 60601-2-44): a comparative study
Journal of Applied Clinical Medical Physics
, John Wiley & Sons 2018, Vol. 19, (4) : 281-289
Bujila, Robert; Kull, Love; Danielsson, Mats; et al.
2017
Modeling ion recombination in liquid ionization chambers: Improvement and analysis of the two-dose-rate method
Medical physics (Lancaster)
, John Wiley & Sons 2017, Vol. 44, (11) : 5977-5987
Andersson, Jonas; Tölli, Heikki
2017
Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report)
Physica medica (Testo stampato)
, Vol. 39 : 67-72
de Las Heras Gala, Hugo; Torresin, Alberto; Dasu, Alexandru; et al.
2017
The dosimetric impact of including the patient table in CT dose estimates
Physics in Medicine and Biology
, Vol. 62, (23) : 538-547
Nowik, Patrik; Bujila, Robert; Kull, Love; et al.
2017
Influence of lead apron shielding on absorbed doses from cone-beam computed tomography
Radiation Protection Dosimetry
, Vol. 175, (1) : 110-117
Rottke, Dennis; Andersson, Jonas; Ejima, Ken-Ischiro; et al.
2017
Patient centering effects on Size-Specific Dose Estimates (SSDE)
EuroSafe Imaging 2017
Åhlström Riklund, Katrine; Andersson, Jonas; Granberg, Christoffer; et al.
2016
Patient organ dose with computed tomography - a review of present methodology and DICOM information: executive summary of the joint report of AAPM task group 246 and EFOMP
ECR 2016 Book of Abstracts
Andersson, Jonas; Pavlicek, William
2016
Characterization of Beam Shaping Filters and Photon Spectra From HVL Profiles in CT
58th AAPM Annual Meeting and Exhibition 2016, Washington, DC, USA, Jul 31 - Aug 4, 2016
Bujila, R.; Kull, L.; Nowik, P.; et al.
2016
Quality control for cone beam CT devices: The EFOMP guidelines for assessing image quality and dose
ECR 2016
de las Heras, Hugo; Rampado, Osvaldo; Andersson, Jonas; et al.
2016
Source modeling for Monte Carlo dose calculation of CT examinations with a radiotherapy treatment planning system
Medical physics (Lancaster)
, Vol. 43, (11) : 6118-6128
Källman, Hans-Erik; Holmberg, Rickard; Andersson, Jonas; et al.
2016
Upper limits of the photon fluence rate on CT detectors: case study on a commercial scanner
Medical physics (Lancaster)
, American Association of Physicists in Medicine 2016, Vol. 43, (7) : 4398-4411
Persson, Mats; Bujila, Robert; Nowik, Patrik; et al.
2016
Experiences with large-scale radiation exposure monitoring in Västerbotten County, Sweden
EuroSafe Imaging 2016
Åhlström Riklund, Katrine; Andersson, Jonas; Lundman, Josef; et al.
2015
Radiation Dosimetry for CBCT – Quality Control and Applied Dosimetry
17th CT users group meeting, Childon, UK, December 15, 2015
Andersson, Jonas
2015
Characterization of HPGe detectors using Computed Tomography
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
, Elsevier 2015, Vol. 785, (11 June 2015) : 21-25
Hedman, Angelica; Gogani, J. Bahar; Granström, M.; et al.
2015
A Reference Organ Dose Database for Body CT Examination Based On AAPM 246
Medical physics (Lancaster)
, Vol. 42, (6) : 3746-3746
Tian, X.; Segars, P.; Andersson, Jonas; et al.
2014
TG246 On Patient Dose From Diagnostic Radiation: Acceptance Testing and Dose Measurements with CT
56th AAPM Annual Meeting and Exhibition 2014, Austin, TX, USA, July 20-24 (2014)
Andersson, Jonas
2013
Fysik och teknik: konventionell planar röntgen
Nuklearmedicin
, Lund: Studentlitteratur AB 2013 : 40-46
Andersson, Jonas
2013
Ion recombination in liquid ionization chambers: development of an experimental method to quantify general recombination
Umeå University medical dissertations
, 1567
Andersson, Jonas
2013
Liquid ionization chamber initial recombination dependence on LET for electrons and photons
Physics in Medicine and Biology
, Institute of Physics Publishing (IOPP) 2013, Vol. 58, (12) : 4225-4236
Johansson, Erik; Andersson, Jonas; Johansson, Lennart; et al.
2012
On the property of measurements with the PTW microLion chamber in continuous beam
Medical physics (Lancaster)
, American Association of Physicists in Medicine 2012, Vol. 39, (8) : 4775-4787
Andersson, Jonas; Johansson, Erik; Tölli, Heikki
2012
A comparison of different experimental methods for general recombination correction for liquid ionization chambers
Physics in Medicine and Biology
, Institute of Physics Publishing (IOPP) 2012, Vol. 57, (21) : 7161-7175
Andersson, Jonas; Kaiser, Franz-Joachim; Gómez, Faustino; et al.
2012
The Use of Liquid Ionization Chambers in Radiation Dosimetry
World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012 Beijing, China
Andersson, Jonas; Tölli, Heikki
2011
Application of the two-dose-rate method for general recombination correction for liquid ionization chambers in continuous beams
Physics in Medicine and Biology
, Vol. 56, (2) : 299-314
Andersson, Jonas; Tölli, Heikki
2008
Radiation doses in examination of lower third molars with computed tomography and conventional radiography.
Dento-Maxillo-Facial Radiology
, Vol. 37, (8) : 445-452
Öhman, A; Kull, Love; Andersson, Jonas; et al.
View publications in DiVA
+ Show more
- Show less